This FAQ talks about direct receiver access in Keyight's high-performance USB and PXI VNA models. The same information is applicable to four-pourt E5080B model configurations, too.Question
Do the high-performance USB VNA and PXI VNA models offer a direct receiver access feature?Answer
Yes. P502xA Series USB VNA or M980xA PXI VNA support configurations of direct receiver access (DRA mode) for high power measurements using an external booster amp and couplers. 4 or 6-port options for the P502xA are available. The same information is applicable to four-pourt E5080B model configurations, too. Look here:Direct Receiver Access – VNA Help
http://na.support.keysight.com/pxi/help/latest/help.htm#system/direct_receiver_access.htm
Additionally, in 2020 Keysight introduced M981xA receiver only PXI modules that are used in conjunction with M980xA PXI VNA modules as part of a PXI form factor Vector Component Analyzer (VCA) system for applications that involve high power device test setups. The model numbers for the VCA systems are:
- M9815AS 100 kHz to 26.5 GHz
- M9816AS 100 kHz to 32 GHz
- M9817AS 100 kHz to 44 GHz
- M9818AS 100 kHz to 53 GHz